54

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

Chapter 6

Configuration Guidelines

Table 7 - Direct Drive Linear Stage Distance Unit Settings

Table 6 - Scaling Parameters Values

User Unit Scaling Parameters

(1)

Distance Units for Ball Screw Linear Stages

Millimeters Inches

MPAS-xxxxxx-V05xxA MPAS-xxxxxx-V20xxA

MPAS-xxxxxx-V05xxA MPAS-xxxxxx-V20xxA

Velocity Label

mm/s

mm/s

in./s

in./s

Velocity Scale

26214.4

6553.6

665845.76

166461.44

Position Label

mm

mm

in.

in.

Position Scale

26214.4

6553.6

665845.76

166461.44

Acceleration Label

mm/s/s

mm/s/s

in./s/s

in./s/s

Acceleration Scale

26214.4

6553.6

665845.76

166461.44

(1) User units are determined by the screw lead of the linear stage. The screw lead is defined in linear units of travel per revolution. For example, the travel per revolution of an MPAS-xxxxxx-V05xxA

is 5 mm/

rev and that of an MPAS-xxxxxx-V20xxA is 20 mm/rev. MP-Series linear stages with a ball screw use a feedback device that provides 128 sin/cos cycles per revolution of the motor. The Ultra3000 drive
interpolates this signal by an additional 1024, causing the maximum count per internal motor revolution of the linear stage to be 131,072 counts/rev.

User Unit Scaling Parameters Distance

Units

Millimeters Inches

Velocity Label

mm/s

in./s

Velocity Scale

200

5080

Position Label

mm

in.

Position Scale

200

5080

Acceleration Label

mm/s/s

in./s/s

Acceleration Scale

200

5080