Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 76

Advertising
background image

76

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

Appendix A

Dimensions

Figure 16 - MP-Series Linear Stages (MPAS-A/B6xxx1/2-VxxSxA)

7.6

(0.30)

239

(9.41)

165

(6.50)

(4X) M6 x 1.0-6H

37.0
(1.46)

12.0 (0.47)

25.0
(0.98)

25.0

(0.98)

167

(6.57)

165

(6.50)

54.5
(2.15)

(4X)

Ø 7.0 (0.28) Thru

Pilot Hole

45.0 (1.80)

130

(5.12)

30.0
(1.18)

125.5
(4.94)

46.8

(1.84)

181.5
(7.15)

8.5

(0.33)

31.9

(1.25)

92.0

(3.62)

150

(5.90)

123.8
(4.87)

Dimensions are in mm (in.)

Detail A

120 (4.72)
Toe Clamp/Tee Nut Spacing

Ø 13.0 (0.51) Through

Access Point to Lubricate

Ball Screw Nut

See Detail A

30.5 (1.20)
Mechanical Overtravel

(4X) M10 x 1.5-6H Through (2 per end cap)

Access point for lubricating linear bearings.

Provision to use lifting hooks (not provided).

Ground Screw

M5 x 0.8-6H

T- Nut
Mount to base by using
M6 x 1.0 hardware (optional accessory).

9.3 (0.37)
Depth, max

(S) Stage Length

(OAL) Overall Length

Toe Clamp is standard for

covered stages. Mount to base

by using M6 x 1.0 socket cap screw.

0.025 / 300 x 300 (0.001 / 12.0 x 12.0)

Flatness requirement for the surface

that this stage is being mounted to.

30.5 (1.20)

Mechanical Overtravel

The overall length (OAL) is measured to

the head of the screws that secure the

motor endcap.

Cat. No.
MPAS-

S

OAL
(5 mm/rev)

(1)

OAL
(20 mm/rev)

(2)

Cat. No.
MPAS-

S

OAL
(5 mm/rev)

(3)

OAL
(20 mm/rev)

(2)

mm (in.)

mm (in.)

mm (in.)

mm (in.)

mm (in.)

mm (in.)

A/B6012x-VxxSxA

470 (18.5)

569 (22.4)

594 (23.4)

A/B6036x-VxxSxA

710 (28.0)

809 (31.9)

834 (32.8)

A/B6018x-VxxSxA

530 (20.9)

629 (24.8)

654 (25.7)

A/B6042x-VxxSxA

770 (30.3)

869 (34.2)

894 (35.2)

A/B6024x-VxxSxA

590 (23.2)

689 (27.1)

714 (28.1)

A/B6054x-VxxSxA

890 (35.0)

989 (38.9)

1014 (39.9)

A/B6030x-VxxSxA

650 (25.6)

749 (29.5)

774 (30.5)

A/B6066x-VxxSxA

1010 (39.8)

1109 (43.7)

1134 (44.6)

(1) If MPAS-A/B6xxx-V05S4A linear stage with brake, add 39 mm (1.53 in.) to dimension OAL.
(2) If MPAS-A/B6xxx-V20S4A linear stage with brake, add 39 mm (1.53 in.) to dimension OAL.
(3) If MPAS-A/B6xxx-V05S4A linear stage with brake, add 39 mm (1.53 in.) to dimension OAL.

Advertising