Rockwell Automation MD65 Profibus Communication Card User Manual
Page 62
8-2
PROFIBUS Communications Module
Figure 8.2 shows that the Single Drive mode provides the possibility
of connecting one additional external peripheral.
Multi-Drive mode is an alternative to the typical network installation,
where a single Profibus node can consist of one to five drives (see
figure 8.3). The first drive must be a MD65 with a MDCOMM-PBUS
module. The remaining drives can be MD65 or MD60 drives that are
daisy-chained over RS-485 with the first drive.
Figure 8.2 – MDI Peripheral Devices for Single Mode Connection
Esc
ALT
Prog
LANG
DISP
JOG
7
8
9
4
5
6
1
2
3
.
0
DEL
ALT
+/-
LANG
DISP
PROG
JOG
MDI
Figure 8.3 – Multi-Drive Mode Example for Network
Profibus
up to 5 drives per node
MD65
MDCOMM-PBUS
Up to 4 MD65 or MD60 Drives
AK-U0-RJ45-TB2P
Connector with 3rd Party
Terminating Resistor
AK-U0-RJ45-TB2P
Connector with 3rd Party
Terminating Resistor
AK-U0-RJ45-TB2P
RS-485