Edit the drive parameters, Edit the drive, Parameters – Rockwell Automation 1768-L43 CompactLogix System Quick Start User Manual

Page 143: Required for ethernet/ip system

Advertising
background image

Publication IASIMP-QS003B-EN-P - October 2009

143

Create a PowerFlex 70 Application Chapter 11

Edit the Drive Parameters

Required for EtherNet/IP System

1. Double-click the

Parameter List.

2. Enter the following

parameters:

3. Click OK.

The parameters are
loaded to the drive.

Parameter

Name

Value

Parameter 61

Autotune

Ready

Parameter 90

Speed Ref A Sel

DPI Port 5

Parameter 361

Digital In1 Sel

Not Used

Parameter 362

Digital In2 Sel

Not Used

Parameter 363

Digital In3 Sel

Not Used

Parameter 364

Digital In4 Sel

Not Used

Parameter 365

Digital In5 Sel

Not Used

Parameter 366

Digital In6 Sel

Not Used

Advertising