Publication IASIMP-QS003B-EN-P - October 2009
145
Create a PowerFlex 70 Application Chapter 11
Create a DeviceNet Scanlist
Required for DeviceNet System
1. Move the controller
keyswitch to Program
and go offline.
2. If RSNetWorx for
DeviceNet is open, skip
to step 3.
If RSNetWorx for
DeviceNet is not open:
a. In RSLogix, right-click
1769-SDN and select
Properties.
b. On the RSNetWorx
tab, click the
RSNetWorx button.
3. In RSNetWorx for
DeviceNet, click the Who
Active button.
4. Click OK and
RSNetWorx will browse
the network.
If the drive does not
display, or displays with
an error regarding the
EDS file, see
Knowledgebase article
20539.