Publication IASIMP-QS015C-EN-P - August 2011

163

Logix Communication and Controller Configuration

Appendix A

6. Select Dynamic and use DHCP to obtain the network

configuration.
If Use DHCP to contain network configuration is
grayed out, you may need to use ControlFlash
software to upgrade the latest firmware in the
Ethernet module. Refer to

Ethernet Module

Firmware Update Using ControlFLASH Utility

on

page 163

to get the latest updates.

7. Click Apply.

8. Click OK.

You can now exit RSLinx Classic software.

Ethernet Module Firmware Update Using ControlFLASH Utility

Follow these steps to update firmware in the Ethernet module by using the ControlFLASH utility.

1. Make sure the network is connected.

2. Select the ControlFLASH utility from the Tools

menu or launch from Programs in your PC Start
menu.