Connecting the devicenet, Armorconnect to your, Armorstart device – Rockwell Automation 284D On-Machine ArmorStart Accelerator Toolkit User Manual

Page 50

Advertising
background image

50

Publication IASIMP-QS015C-EN-P - August 2011

Chapter 2

System Layout and Wiring

Connecting the DeviceNet ArmorConnect to Your ArmorStart Device

The ArmorConnect power media offers both three-phase and control power cable system of cord sets, patch
cords, receptacles, tees, reducers, and accessories for use with the ArmorStart distributed motor controller.
These cable system components allow quick connection of ArmorStart distributed motor controllers,
reducing installation time. They provide for repeatable, reliable connection of the three-phase and control
power to the ArmorStart distributed motor controller and motor by providing a plug-and-play environment
that also avoids system miss wiring. When specifying power media for the ArmorStart distributed motor
controllers (Bulletin 280/281, 283, and 284), use only the Bulletin 280 ArmorConnect power media.

Three-phase Power System Overview

ID

Cat. No.

Description

1

280-PWR35A-Mx

1

1

x” represents number needed for cable length. See the three-phase power media section of the ArmorStart Distributed MotorController and ArmorConnect Power Media
Selection Guide, publication

280-SG001,

for available lengths.

Three-phase power trunk–Patchcord cable with integral female or male connector on each end.

2

280-PWR22A-Mx

1

Three-phase drop cable–Patchcord cable with integral female or male connector on each end.

3

280-T35

Three-Phase power tees and reducer–Tee connects to a single drop line to trunk with quick change connectors.

280-RT35

Reducing tee connects to a single drop line (mini) to trunk (quick change) connector.

280-RA35

Reducer connects from quick change male connector to mini female connector.

4

280-M35F-M1

Three-phase power receptacles–Female receptacles are a panel mount connector with flying leads

RESET

OFF

Bulletin 280/281 ArmorStart

Bulletin 283 ArmorStart

Bulletin 284 ArmorStart

PLC

Bulletin 1492FB

Branch Circuit

Protective Device

Bulletin 1606

Power Supply

Enclosure

Bulletin 800F

Emergency Stop

Pushbutton

1606-XLSDNET4

DeviceNet

Power Supply

Advertising