Integrate armorstart aoi into, Your application program, Routines – Rockwell Automation 284D On-Machine ArmorStart Accelerator Toolkit User Manual

Page 96: Go to

Advertising
background image

96

Publication IASIMP-QS015C-EN-P

Chapter 5

Faceplate Logix Integration

2. Set the tag Inp_NumRowsVis for your ArmorStart Add-On Instruction to the number of rows that you

will use on the Equipment Status Faceplate.

a. Under the Add-On Instructions folder in the system tree,

double-click the ArmorStart Add-On Instruction that you will
use for the device in row 1.

b. Under the Parameters tab, find the Inp_NumRowsVis tag and

check the Vis box to make the tag visible on the AOI.

This tag only needs to be set for the Add-On Instruction used
in row 1 of the faceplate.

The default number of rows, ‘Inp_NumRowsVis’ is set to 9. You can change the number of rows
displayed here by changing the default, or edit the field directly on the Add-On Instruction when
creating your ladder rungs.

Integrate ArmorStart AOI into Your Application Program Routines

Follow these steps to add ArmorStart Add-On Instruction into your application program routines for each
of your ArmorStart devices that you have configured.

1. Open the intended program routine.

2. Create a rung.

3. Click the Add-On Instruction tab.