Error Code

Message Information

Action

Check presence, reinstall or reconnect, then reattempt the
update. If the issue persists, see

Getting Help

.

HWC4015

Message

Link Tuning error detected.

Details

CMC has old firmware. After updating the firmware the CMC
will recognize the device.

Action

Update the CMC firmware. If the issue persists, see

Getting

Help

.

HWC5001

Message

<name> is offline.

Action

If unexpected, check presence, then reinstall or reconnect.

HWC5002

Message

A fabric mismatch detected on <name>.

Details

The fabric type for the IOM and PCIe mezzanine cards must
match.

Action

Check chassis fabric type in CMC GUI and compare to the
type of IOM or PCIe mezzanine card.

HWC5004

Message

A link tuning failure detected on <name>.

Details

CMC has old firmware. After updating the firmware the CMC
will recognize the device.

Action

Update the CMC firmware. If the issue persists, see

Getting

Help

.

HWC5006

Message

A failure is detected on <name>.

Action

If the issue persists, see

Getting Help

.

HWC5008

Message

Console is not available for the <name>.

Action

If the issue persists, see

Getting Help

.

HWC5010

Message

<name> cannot detect any hosts.

Action

If the issue persists, see

Getting Help

.

HWC5014

Message

<name> is not functional and is powered off.

Action

If the issue persists, see

Getting Help

.