Dell PowerEdge M820 (for PE VRTX) User Manual

Page 141

Advertising
background image

Error Code

Message Information

LCD Message

Control panel temperature is outside of range.

Details

Ambient air temperature is too warm or one or more fans
may have failed.

Action

Check the system operating environment and review event
log for fan failures.

TMP0134

Message

The control panel temperature is outside of the allowable
range.

LCD Message

Control panel temperature is outside of range.

Details

Ambient air temperature is too warm or cool.

Action

Check the system operating environment and review event
log for fan failures.

VLT0100

Message

Processor module <name> voltage is less than the lower
warning threshold.

LCD Message

Processor module <name> voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Remove the processor module. Inspect processor

socket for bent pins.

3.

If the issue persists, see

Getting Help

.

VLT0101

Message

Processor module <name> voltage is less than the lower
critical threshold.

LCD Message

Processor module <name> voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Remove the processor module. Inspect processor

socket for bent pins.

3.

If the issue persists, see

Getting Help

.

141