Error Code

Message Information

VLT0203

Message

The system board <name> voltage is greater than the upper
critical threshold.

LCD Message

System board voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

3.

If the issue persists, see

Getting Help

.

VLT0204

Message

The system board <name> voltage is outside of the allowable
range.

LCD Message

System board voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

3.

If the issue persists, see

Getting Help

.

VLT0206

Message

The memory module <number> <name> voltage is less than
the lower warning threshold.

LCD Message

Memory module <number> <name> voltage is outside of
range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

144