Figure 3. Hard-drive/SSD indicators

1.

drive activity indicator (green)

2.

drive status indicator (green and amber)

NOTE: If the drive is in Advanced Host Controller Interface (AHCI) mode, the status LED (on the
right side) does not function and remains off.

Drive-Status Indicator Pattern

Condition

Blinks green two times per second

Identifying drive or preparing for removal

Off

Drive ready for insertion or removal

NOTE: The drive status indicator remains off

until all drives are initialized after system

power is applied. Drives are not ready for

insertion or removal during this time.

Blinks green, amber, and then turns off

Drive predicted failure

Blinks amber four times per second

Drive failed

Blinks green slowly

Drive rebuilding

Steady green

Drive online

Blinks green three seconds, amber three seconds,
and off six seconds

Rebuild aborted

Related documentation

WARNING: See the safety and regulatory information that shipped with your system. Warranty
information may be included within this document or as a separate document.

• The Getting Started Guide for the VRTX enclosure provides an overview of the VRTX enclosure and

the server modules, setting up your system, and technical specifications.

• The Dell PowerEdge VRTX Enclosure Owner’s Manual provides information about the VRTX enclosure

features and describes how to troubleshoot the enclosure and install or replace the enclosure's

components. This document is available online at dell.com/poweredgemanuals.