Error Code

Message Information

Details

PXE is one way to boot a system from the network.

Action

Check the network and PXE server configuration.

SEL1306

Message

Invalid boot sector found.

Details

The disk in the drive is not formatted correctly or does not
contain the necessary operating system files.

Action

Replace diskette with a bootable disk.

SEL1308

Message

A time-out occurred while waiting for user to select a boot
source.

Details

The system has failed to boot to an operating system and
needs the user to select a boot source.

Action

Select boot source within the time allowed.

SEL1501

Message

Chassis management controller (CMC) redundancy is lost.

Details

An action or failure has taken place that breaks CMC
redundancy.

Action

Check the CMC network cables and network connections.
Check that CMC firmware versions match.

SEL1502

Message

Chassis management controller (CMC) redundancy is
degraded.

Details

An action or failure has taken place that breaks CMC
redundancy.

Action

Check the CMC network cables and network connections.
Check that CMC firmware versions match.

SEL1504

Message

The chassis management controller (CMC) is not redundant.
Insufficient resources to maintain normal operations.

Details

There is not enough available power for two CMC's to
operate.

Action

Check the overall power consumption and power status.

SEL1506

Message

Lost communications with Chassis Group Member
<number>.

Details

The primary CMC has lost communication with the indicated
member CMC.