background image

Error Code

Message Information

Details

The <name> battery is either missing, bad, or unable to
charge due to thermal issues.

Action

Check system fans. Replace the <name> battery.

BAT0019

Message

The <name> battery is absent.

LCD Message

The <name> battery is absent. Check battery.

Details

The failed or missing <name> battery may reduce system
performance.

Action

Check system fans. Replace the <name> battery.

CBL0006

Message

Multiple storage controllers are incorrectly connected to the
same backplane <Bay ID>.

Details

Unsupported backplane configuration.

Action

Check backplane configuration. Reconnect cable. If the issue
persists, see

Getting Help

.

CPU0000

Message

CPU <number> has an internal error (IERR).

LCD Message

CPU <number> has an internal error (IERR).

Details

System event log and OS logs may indicate that the
exception is external to the processor.

Action

Review System Event Log and Operating System Logs. If the
issue persists, see

Getting Help

.

CPU0001

Message

CPU <number> has a thermal trip (over-temperature) event.

LCD Message

CPU <number> has a thermal trip. Check CPU heat sink.

Details

The processor temperature increased beyond the
operational range.

Action

Review logs for fan failures, replace failed fans. If no fan
failures are detected, check inlet temperature (if available)
and reinstall processor heat-sink.

CPU0002

Message

CPU <number> has failed the built-in self-test (BIST).

Action

1.

Turn system off and remove input power for one

minute. Reapply input power and turn system on.

2.

Make sure the processor is seated correctly.

3.

If the issue persists, see

Getting Help

.

90