Dell PowerEdge M820 (for PE VRTX) User Manual

Page 116

Advertising
background image

Error Code

Message Information

Action

If unintended, verify drive installation. Remove and re-seat
the indicated disk. If the issue persists, see

Getting Help

.

PDR1001

Message

Fault detected on drive <number> in disk drive bay <bay>.

LCD Message

Fault detected on drive <number> in disk drive bay <bay>.
Check drive.

Details

The controller detected a failure on the disk and has taken
the disk offline.

Action

Re-seat the failed drive. If the issue persists, see

Getting

Help

.

PDR1002

Message

A predictive failure detected on drive <number> in disk drive
bay<bay>.

Details

The controller received a SMART error from the drive. The
drive is operational but needs replacement.

Action

The drive will need replacement at the next service window.

PDR1016

Message

Drive <number> is removed from disk drive bay <bay>.

LCD Message

Drive <number> removed from disk drive bay <bay>. Check
drive.

Details

The controller detected that the drive was removed.

Action

Verify drive installation. Re-seat the failed drive. If the issue
persists, see

Getting Help

.

PDR1024

Message

Drive mismatch detected for drive <number> in disk drive
bay <bay>.

LCD Message

Drive mismatch detected for drive <number> in bay <bay>.
Install correct drive type.

Details

The installed disk does not meet the array requirements, for
example a SATA disk may not operate in an array containing
SAS drives.

Action

Verify that the disk meets the array requirements.

PST0128

Message

No memory is detected.

LCD Message

No memory is detected. Inspect memory devices.

Details

System BIOS was unable to detect memory in the system .

116