Error Code

Message Information

LCD Message

PSU redundancy degraded. Check PSU cables.

Details

The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.

Action

Check the event log for power supply failures. Review
system configuration and power consumption.

PWR1001

Message

The system performance was degraded.

LCD Message

System performance degraded. Check PSUs and system
configuration.

Details

To avoid shutdown, system performance has been degraded.

Action

Review system configuration and system logs for thermal or
environmental failures and warnings.

PWR1002

Message

The system performance degraded because of thermal
protection.

Details

To avoid shutdown, system performance has been degraded.

Action

Review system configuration and system logs for thermal or
environmental failures and warnings.

PWR1003

Message

The system performance degraded because cooling capacity
has changed.

Details

The current power supply configuration does not meet the
platform requirements to enable redundancy. If a power
supply fails the system may shutdown.

Action

If unintended, review system configuration and power
consumption and install power supplies accordingly. Check
power supply status for failures.

PWR1004

Message

The system performance degraded because power capacity
has changed.

Details

The system may power down or operate in a performance
degraded state.

Action

Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.

PWR1005

Message

The system performance degraded because the user-
defined power capacity has changed.