Dell PowerEdge M820 (for PE VRTX) User Manual

Page 115

Advertising
background image

Error Code

Message Information

Action

Cycle input power, update component drivers, remove and
reinstall the device at the next service window.

PCI3010

Message

A non-fatal IO error detected on a component at bus
<bus>device<device>function <func>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and
reinstall the device at the next service window.

PCI3012

Message

The QuickPath Interconnect (QPI) width degraded.

Details

System performance may be degraded. The bus is not
operating at maximum speed or width.

Action

Reset the system, if the problem persists reinstall processors.

PCI3014

Message

A non-fatal PCIe error detected on a component at slot
<number>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and
reinstall the device at the next scheduled service time.

PDR0001

Message

Fault detected on drive <number>.

LCD Message

Fault detected on drive <number>. Check drive.

Details

The controller detected a failure on the disk and has taken
the disk offline.

Action

Remove and re-seat the failed disk. If the issue persists, see

Getting Help

.

PDR0002

Message

A predictive failure detected on drive <number>.

Details

The controller received a SMART error from the drive. The
drive is operational but needs replacement.

Action

The drive will need replacement at the next service window.

PDR0016

Message

Drive <number> is removed.

LCD Message

Drive <number> is removed. Check drive.

Details

The controller detected a drive removal.

115