background image

Error Code

Message Information

MEM1016

Message

Memory device at location <location> is not installed
correctly.

LCD Message

Memory <location> is not installed correctly. Reinstall.

Details

The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.

Action

Check the memory configuration. Re-seat the memory
modules. If the issue persists, see

Getting Help

.

MEM1205

Message

Memory mirror redundancy is lost. Check memory device at
location(s) <location>.

LCD Message

Memory mirror lost on <location>. Power cycle system.

Details

The memory may not be seated correctly, misconfigured, or
has failed.

Action

Check the memory configuration. Re-seat the memory
modules. If the issue persists, see

Getting Help

.

MEM1206

Message

Memory mirror redundancy is degraded. Check memory
device at location <location>.

Details

The memory may not be seated correctly, misconfigured, or
has failed.

Action

Check the memory configuration. Re-seat the memory
modules. If the issue persists, see

Getting Help

.

MEM1208

Message

Memory spare redundancy is lost. Check memory device at
location <location>.

LCD Message

Memory spare lost on <location>. Power cycle system.

Details

Memory sparing is no longer available.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM1212

Message

Memory redundancy is lost.

Details

The memory may not be seated correctly, misconfigured, or
has failed.

Action

Review system logs for memory exceptions. reinstall
memory at location <location>

MEM1214

Message

Memory redundancy is degraded.

107