Error Code

Message Information

PCI1356

Message

A bus uncorrectable error was detected on a component at
slot <number>.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1358

Message

A fatal error was detected on a component at slot <number>.

LCD Message

Fatal error on slot <number>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1360

Message

A bus fatal error was detected on a component at slot
<number>.

LCD Message

Bus fatal error on slot <number>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1362

Message

Bus performance degraded for a component at slot
<number>.

Details

System performance may be degraded. The bus is not
operating at maximum speed or width.

Action

Cycle input power, update component drivers, remove and
reinstall the device at the next scheduled service time.

PCI2000

Message

A fatal IO error detected on a component at bus
<bus>device<device>function <func>.

LCD Message

Fatal IO error on bus <bus> device <device> function <func>.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, remove and
reinstall the device.

113