Dell PowerEdge M820 (for PE VRTX) User Manual

Page 94

Advertising
background image

Error Code

Message Information

4.

If the issue persists, see

Getting Help

.

CPU0203

Message

CPU <number> <name> voltage is greater than the upper
critical threshold.

LCD Message

CPU <number> <name> voltage is outside of range. Re-seat
CPU.

Details

High voltages may be the result of problem with the voltage
regulator or a problem with the processor. Elevated voltages
may result in damage to the processor or other system
electrical components. The system may power down.

Action

1.

Turn system off and remove input power for one

minute.

2.

Reapply input power and turn system on.

3.

Ensure the processor is seated correctly.

4.

If the issue persists, see

Getting Help

.

CPU0204

Message

CPU <number> <name> voltage is outside of range.

LCD Message

CPU <number> <name> voltage is outside of range. Re-seat
CPU.

Details

Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.

Action

1.

Turn system off and remove input power for one

minute.

2.

Ensure the processor is seated correctly.

3.

Reapply input power and turn system on.

4.

If the issue persists, see

Getting Help

.

CPU0700

Message

CPU <number> initialization error detected.

LCD Message

CPU <number> initialization error detected. Power cycle
system.

Details

System BIOS was unable to initialize the processor.

Action

1.

Turn system off and remove input power for one

minute.

2.

Ensure the processor is seated correctly.

3.

Reapply input power and turn system on.

94