Dell PowerEdge M820 (for PE VRTX) User Manual

Page 117

Advertising
background image

Error Code

Message Information

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0129

Message

Memory is detected, but is not configurable.

LCD Message

Memory is detected, but is not configurable. Check memory
devices.

Details

System BIOS detected memory, but was unable to configure
the memory for system operation.

Action

Compare system memory installation to supported system
memory configurations.

PST0130

Message

Memory is configured, but not usable.

LCD Message

Memory is configured, but not usable. Check memory
devices

Details

The system BIOS encountered device failures or speed
configurations that resulted in unused memory.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0131

Message

System BIOS shadow failed.

LCD Message

System BIOS shadow failed. Check memory devices.

Details

Memory errors occurred copying BIOS image into system
memory.

Action

Remove input power. Reduce system memory to minimum
configuration and apply input power.

PST0132

Message

CMOS failed.

LCD Message

CMOS failed. Power cycle system.

Details

System BIOS detected a failure with CMOS memory during
system POST.

Action

Check system event log for CMOS battery exceptions.
Remove and reapply input power. If the issue persists, see

Getting Help

.

PST0133

Message

DMA controller failed.

LCD Message

DMA controller failed. Power cycle system.

117

Advertising