Dell PowerEdge M820 (for PE VRTX) User Manual

Page 143

Advertising
background image

Error Code

Message Information

VLT0200

Message

The system board <name> voltage is less than the lower
critical threshold.

LCD Message

System board voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Remove the processor module. Inspect processor

socket for bent pins.

3.

If the issue persists, see

Getting Help

.

VLT0201

Message

The system board <name> voltage is less than the lower
warning threshold.

LCD Message

System board voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

3.

If the issue persists, see

Getting Help

.

VLT0202

Message

The system board <name> voltage is greater than the upper
warning threshold.

LCD Message

System board voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

3.

If the issue persists, see

Getting Help

.

143