Dell PowerEdge M820 (for PE VRTX) User Manual

Page 105

Advertising
background image

Error Code

Message Information

Details

The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0005

Message

Persistent correctable memory error limit reached for a
memory device at location(s) <location>.

LCD Message

Persistent correctable memory error limit reached for
<location>. Re-seat memory.

Details

The memory is operational. This an early indicator of a
possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0007

Message

Unsupported memory configuration; check memory device
at location <location>.

LCD Message

Unsupported memory configuration. Check memory
<location>.

Details

The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.

Action

Check the memory configuration. Re-seat the memory
modules. If the issue persists, see

Getting Help

.

MEM0009

Message

Memory device at location <location> is throttled.

Details

System performance is degraded.

Action

If unexpected, review system logs for power or thermal
exceptions.

MEM0010

Message

Memory device at location <location> is over heating.

LCD Message

Memory device <location> is over heating. Check fans.

Details

System performance is degraded.

Action

If unexpected, review system logs for power or thermal
exceptions.

MEM0022

Message

Memory device at location <location> is absent.

Details

The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.

105