Environmental

NOTE: Outside the standard operating
temperature (10 °C to 35 °C), the system can
operate down to 5 °C or up to 40 °C for a
maximum of 10% of its annual operating hours.

For temperatures between 35 °C and 40 °C, de-rate

maximum allowable dry bulb temperature by 1 °C

per 175 m above 950 m (1 °F per 319 ft).

≤ 1% of annual operating hours

–5 °C to 45 °C at 5% to 90% RH with 26 °C dew
point.

NOTE: Outside the standard operating
temperature (10 °C to 35 °C), the system can
operate down to –5 °C or up to 45 °C for a
maximum of 1% of its annual operating hours.

For temperatures between 40 °C and 45 °C, de-

rate maximum allowable dry bulb temperature by 1

°C per 125 m above 950 m (1 °F per 228 ft).

Expanded operating temperature restrictions

• Do not perform a cold startup below 5 °C
• Install only 87 mm wide heat sinks
• Do not install more than 40 DIMMs
• The following do not support expanded

operating temperature range:

– PCIe SSD
– Express flash
– LRDIMMs
– 130 W four-core processors