Dell PowerEdge M820 (for PE VRTX) User Manual

Page 102

Advertising
background image

Error Code

Message Information

HWC5031

Message

IO module <number> is offline.

Details

The CMC has powered off the IOM.

Action

If the issue persists, see

Getting Help

.

HWC5032

Message

A fabric mismatch detected on IO module <number>.

Details

The fabric type for IOM's on the same chassis fabric must
match.

Action

Check chassis fabric type in CMC GUI and compare to the
type of both IOM's.

HWC5034

Message

A link tuning failure detected on IO module <number>.

Details

Link tuning table not supported for this IO modular.

Action

Update the CMC firmware. If the issue persists, see

Getting

Help

.

HWC5036

Message

A failure is detected on IO module <number>.

Details

The IOM module performance may be impacted.

Action

If the issue persists, see

Getting Help

.

HWC6000

Message

The <name> controller is offline.

Details

Information and status from the controller is unavailable.

Action

Remove and reapply input power. If the issue persists, see

Getting Help

.

HWC6002

Message

The <name> controller is stuck in boot mode.

Details

Information and status from the controller is unavailable.

Action

Remove and reapply input power. If the issue persists, see

Getting Help

.

HWC6003

Message

The <name> controller is booting.

HWC6004

Message

Cannot communicate with <name> controller.

Details

Information and status from the controller is unavailable.

102