Dell PowerEdge M820 (for PE VRTX) User Manual

Page 96

Advertising
background image

Error Code

Message Information

5.

If the issue persists, see

Getting Help

.

CPU0704

Message

CPU <number> machine check error detected.

LCD Message

CPU <number> machine check error detected. Power cycle
system.

Details

System event log and operating system logs may indicate
that the exception is external to the processor.

Action

1.

Check system and operating system logs for exceptions.

If no exceptions are found, continue.

2.

Turn system off and remove input power for one

minute.

3.

Ensure the processor is seated correctly.

4.

Reapply input power and turn system on.

5.

If the issue persists, see

Getting Help

.

CPU0801

Message

CPU <number> voltage regulator module failed.

LCD Message

CPU <number> voltage regulator module failed. Re-seat
module.

Details

System performance may be degraded or the system may
fail to operate.

Action

1.

Turn system off and remove input power for one

minute.

2.

Reapply input power and turn system on.

3.

Ensure the processor is seated correctly.

4.

If the issue persists, see

Getting Help

.

CPU0802

Message

A predictive failure detected on CPU <number> voltage
regulator module.

Details

System performance may be degraded or the system may
fail to operate.

Action

1.

Turn system off and remove input power for one

minute.

2.

Reapply input power and turn system on.

3.

Ensure the processor is seated correctly.

4.

If the issue persists, see

Getting Help

.

96