Configuration parameters, continued

Compensator

ON

Switches on the
compensator, which
measures the longitudinal
and transverse tilts of the
vertical axis. The V-angles
are relative to the plumb
line.

OFF

Switches off the
compensator.

appears

in the status display. The V-
angles are relative to the
vertical axis.

The working range of the
two-axis compensator is 6'

(0.10 gon) for each axis.

Hz-Corr.

ON

Switches on the Hz
correction.
The Hz measurements are
corrected for the following
errors:
1. Line-of-sight error
2. Tilting-axis error
3. Standing-axis tilt (only for
compensator ON).

OFF

Switches off the Hz correction.
The Hz measurements are
not corrected.

appears in the status

display.

Examples of compensator / Hz
corrections:

1. Compensator ON, Hz corrections

ON.
The V-angles are relative to the
plumb line. The Hz measurements
are corrected for line-of-sight error,
tilting-axis error and standing-axis
tilt.

2. Compensator ON, Hz corrections

OFF
The V-angles are relative to the
plumb line. The Hz measurements
are not corrected for line-of-sight
error, tilting-axis error or standing-
axis tilt.

3. Compensator OFF, Hz corrections

ON
The V-angles are relative to the
standing axis. The Hz
measurements are corrected for
line-of-sight error and for tilting-
axis error.

4. Compensator OFF, Hz corrections

OFF
The V-angles are relative to the
standing axis. Hz corrections are
not applied.