Technical specifications – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 153

Advertising
background image

153

TPS1100 - User Manual 2.2.1en

Technical specifications

6

10

12

21

26

45

84

92

D

1

= atmospheric correction [ppm]

p

= air pressure [mbar]

t

= air temperature [°C]

h

= relative humidity [%]

α

= 1 / 273.16

x

= 7.5 t

237.3 + t

+ 0.7857

If the basic value of 60% relative
humidity as used by the EDM is
retained, the maximum possible error
in the calculated atmospheric
correction will be 2 ppm (2 mm / km).

Reduction to mean sea level

∆∆∆∆∆

D

2

The values for

D

2

are always negati-

ve and are derived from the following
formula:

D

2

= reduction to mean sea level

[ppm]

H

= height of EDM above sea

level [m]

R

= 6378 km

Projection distortion

∆∆∆∆∆

D

3

The magnitude of the projection
distortion is in accordance with the
projection system used in a particular
country, for which official tables are
generally available. The following
formula is valid for cylindrical
projections such as that of Gauss-
Krüger:

D

3

= projection distortion [ppm]

X

= northing, distance from

projection zero line with the
scale factor 1 [km]

R

= 6378 km

In countries where the scale factor is
not unity, this formula cannot be
directly applied.

D

2

= -

H
R

· 10

3

D

3

=

X

2

2R

2

· 10

6

Atmospheric correction

∆∆∆∆∆

D

1,

continued