TPS1100 - User Manual 2.2.1en

System functions

6

10

12

21

26

Selecting the EDM ..., continued

Selecting the target type

This line appears only if a
reflectorless instrument is being
used. There is a choice between
"reflectorless" and "reflector".

Wrong target type setting
leads to bad measurements.

Refl.Name

The current reflector is indicated and,
on the next line, the additive constant
associated with it.

Calls the function "Reflector
selection".

Wrong prism setting leads to
bad measurements.

Switch between IR/RL

[ >REF ]

Activates infrared
distance measurement
(with reflector). The last
used ATR/LOCK
settings are
simultaneously
activated.

[ >RL ]

Activates reflectorless
distance measurement.

WARNING:
(only for Extended Range
Instruments)

Reflector-free:
The visible laser beam may only be
used within a controlled area (refer to
chapter "Safety Directions"
) and must
hit a non reflecting material at the
end of its intended path.
Long Range to prisms:
This mode is only permissible from a
distance of 1000 m (3300 ft) from the
telescope. No persons may stay
within the beam path up to 1000 m
(=controlled area; refer to chapter
"Safety Directions"
).

Advertising