Checking and adjusting – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 39

Advertising
background image

39

TPS1100 - User Manual 2.2.1en

Checking and adjusting

6

10

12

21

Confirms readiness to
measure and the display

changes as follows.

Sight the target accurately.

Performs the second
measurement of the horizon-

tal angle.

After the second measurement has
been completed, the old and newly-
determined tilting-axis errors (a) are
displayed.

Stores the new values.

Repeats the complete tilting-
axis error determination
procedure.

Leaves the old values
unchanged.

If the value of the tilting axis
error (a) exceeds 5' 24"

(0.1 gon), the measurements are to
be repeated. If this happens often,
please notify service.

Tilting axis, continued

Main\ Tilting-Axis Error

old new

a Tilt: -0°00'03" 0°00'17"

Accept new value(s)?

YES RETRY

NO

MC

QUIT

Telescope Positioning

Hz- and V-positioning:

set direction(s) to zero.

∆∆∆∆∆

Hz

:

0°00'00"

∆∆∆∆∆

V

:

0°00'00"

OK

ABORT

MC

QUIT

Main\ Tilting-Axis Error

Aim accurately at the same

target in other face

Hz

:

193°19'24"

V

:

269°08'45"

MEAS

MC

QUIT

Advertising