TPS1100 - User Manual 2.2.1en

Checking and adjusting

6

0

2

21

Determines the compensator
index error.
Simultaneous adjustment of
the electronic bubble.

Determines the index error
for the vertical circle
(V-index error).

Defines line-of-sight errors
and, if required, tilting-axis
errors.

Joint determination of the V-
index errors, line-of-sight
errors and, if required, tilting-
axis errors.

Determines the collimation
error of the ATR
(TCA and TCRA versions
only).

Enables the calibration
Log-file (see next

page).

Activating the "Instrument calibration"
function.

Electronic checking and adjusting, continued

The instrument errors reported are
displayed in the sense of an error.
When measurements are being
corrected, they are used in the sense
of corrections and have the opposite
sign to the error.

Main\ Instr. calibration

current

l Compens.long.:

0°00'37"

t Compens.trans:

-0°00'34"

i V-index error:

0°00'28"

c Hz-coll.error:

0°00'20"

a Tilting-axis :

0°00'26"

l,t

i

c/a i/c/a ATR + EXIT

MC

LOGF+

QUIT