System functions – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 71

Advertising
background image

71

TPS1100 - User Manual 2.2.1en

System functions

6

10

12

21

26

EDM test

Toggles between the displays
of measurement frequency

and signal strength. The
measurement frequency display is
similar to the display shown above.

End and return to the
previous dialog.

ON/OFF - key for the acoustic tone.
The stronger the signal the more the
black intensity bar is extending to the
right against 100%. With an already
low signal distances can be
measured.

Displays the signal strength or
measurement frequency.

\ EDM Return Signal

Signal strength

0%

100%

75%

Tone

: OFF

CONT

FREQ

STOP

MC

QUIT

Distance corrections, ppm

A distinction is made between
atmospheric (ppm) and geometric
(ppm) corrections, the sum of which
is used as the final distance
correction.

Settings for the geometrical
correction.

Atmospheric correction

The atmospheric distance
corrections are derived from the dry-
air temperature, air pressure or
height over mean sea-level, and rela-
tive air humidity or wet-air
temperature.

\ ATMOSPHERIC CORR.

Temperature

:

12.0 °C

Atm. press.

:1013.3 mBar

Temp.wet-b.

:

60.0 %

ppm atmospheric :

0.0

ppm geometric

:

0.0

ppm total

:

0.0

CONT GEOM REFRA P<>E %<>T' ATM=0

MC

QUIT

The user can freely define the name
and additive constant (additive
constant) for three reflectors and can
enter the type of reflector (prism or
retro tape). The additive constant is
always given in millimetres [mm]. It is
advisable to determine the additive
constant for "non Leica Geosystems
prisms" on a baseline by means of an
appropriate procedure.
For the reflector to be available for
choice, the reflector type may not be
"None".

\Define new reflector 1

Define type of reflector

Ref.1 Type : Not defined

Ref.1 Name :

-----

Ref.1 Cons :

----- mm

CONT

MC

QUIT