System functions – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 95

Advertising
background image

95

TPS1100 - User Manual 2.2.1en

System functions

6

10

12

21

26

Accessories , continued

If the Hz direction of the instrument is
outside the permitted range but the
target is within it, the instrument can
still rotate itself towards the target.

If the Hz direction of the instrument is
within the permitted range but the
target is outside it, rotation is not
possible and an error report appears.

Hz direction of

instrument

Permitted range

1100Z45

Rotation towards target possible

Eyepiece V begin Starting value for

V-angle of
eyepiece.

Eyepiece V end

Finishing value
for V-angle of
eyepiece.

Lens V begin

Starting value for
V-angle of
objective.

Lens V end

Finishing value
for V-angle of
objective.

Hz limit begin

Starting value for
Hz-direction.

Hz limit end

Finishing value
for Hz-direction.

The functions for transferring
information between the internal
memory and the PC-card are
described below. For transfer via
RS232 the Leica SurveyOffice PC
software is generally used, in which
event the instrument is remote-
controlled and requires no user
interface.

Loading a configuration file (LOAD)

\ Load configuration

Current

:

1100_DEF

New config.

:

-----

Lang.System:

Lang.Confi:

1. ENGLISH

ENGLISH

2. GERMAN

GERMAN

LOAD

MC

QUIT

Selects the configuration files from
the PC-card in the directory
"\tps\conf\".
Displays the languages available in
the system or which belong to the
configuration file.

Loads the new configuration.