Technical specifications – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 143

Advertising
background image

143

TPS1100 - User Manual 2.2.1en

Technical specifications

6

10

12

21

26

45

84

92

Standard

prism

3 prisms

(GPH3)

360°

reflector

Reflector tape

60mm x 60mm

Mini

prism

1

1800 m

(6000 ft)

2300 m

(7500 ft)

800 m

(2600 ft)

150 m

(500 ft)

800 m

(2600 ft)

2

3000 m

(10000 ft)

4500 m

(14700 ft)

1500 m

(5000 ft)

250 m

(800 ft)

1200 m

(4000 ft)

3

3500 m

(12000 ft)

5400 m

(17700 ft)

2000 m

(7000 ft)

250 m

(800 ft)

2000 m

(7000 ft)

Technical specifications

Distance measurement (infrared)
• Type

infrared

• Carrier wave

0.780 µm

• Measuring system

special frequency system

basis 100 MHz = 1.5 m

• EDM type

coaxial

• Display (least count)

1 mm

Atmospheric conditions:
1) Strong haze, visibility 5km; or strong sunlight, severe heat

shimmer

2) Light haze, visibility about 20km; or moderate sunlight,

slight heat shimmer

3) Overcast, no haze, visibility about 40km; no heat shimmer

Shortest measuring distance
• Standard prism

0.2 m

• Mini prism

0.2 m

• 360° Reflector

1.5 m

• 360° Mini prism

1.5 m

• Reflector tape

1.5 m

Measurements can be made to reflector tapes
over the entire range without external ancillary
optics (GDV3).

Range:

(normal and rapid measurement)

Prism constants (additive constants)
• Standard prism

0.0 mm

• Mini prism

+17.5 mm

• 360° Reflector

+23.1 mm

• 360° Mini prism

+30.0 mm

• Reflector tape

+34.4 mm

EDM measuring

programm

Accuracy **

Time per

measurement

Standard

measurement

2 mm + 2 ppm

1.0 sec.

Fast measurement

5 mm + 2 ppm

0.5 sec.

Normal tracking

5 mm + 2 ppm

0.3 sec.

Rapid tracking

10 mm + 2 ppm

< 0.15 sec.

Averaging

2 mm + 2 ppm

-----

** Beam interruptions, severe heat shimmer and moving
objects within the beam path can result in deviations of the
specified accuracy.)

Advertising