System functions
TPS1100 - User Manual 2.2.1en
Setting / defining prisms
Activating the function "Reflector
selection".
Choosing the appropriate prism. The
appropriate additive constant is set
automatically at the same time.
Wrong prism setting leads to
bad measurements.
\ Reflector Selection
Select reflector type
Refl.Name : Leica circ.prism
Add.const. :
0.0mm
DEF 1,2,3 for new reflector
CONT
DEF 1 DEF 2 DEF 3
MC
QUIT
Define reflectors
from other
manufacturers.
,
,
[>RTRK]
Activates rapid distance
tracking.
[>FAST]
Activates rapid distance
measurement.
Tracking
Switch between Fast measurement/Rapid
Switch between Standard/Tracking
[ >STD ]
Activates standard
distance measurement.
[ >TRK ]
Activates distance
tracking.
Advertising