Data format

TPS1100 - User Manual 2.2.1en

6

0

2

21

26

45

84

Separating character (position 16/24)

The last data word of a block must also contain
the separating character and CRLF.

Each data block is allocated a block number by the
recording device. Block numbers start at 1 and increment
automatically.
The block number is contained in the first word of the
block. The first word of a measurement block is the point
number (WI = 11). The first of a code block is the code
number (WI = 41).

The structure of the first word of a data block is as
follows:

Block number

Position

in word

Explanation

Applicable to

16 (24) Blank (separating character)

all words

Position in

word

Explanation

1-2
3-6

7

8-15(23)

16(24)

Word index 11 or 41

Block number (assigned by recording device)

Sign + or -
Point number, code number or text

Blank = separating character