Measurement functions, 66 system functions – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 66

Advertising
background image

66

System functions

TPS1100 - User Manual 2.2.1en

After the instrument height and the
reflector height have been entered,
target the backsight point and measure
the distance and/or the direction.

Measure the distance. The
difference between the

calculated distance and the
measured distance to the backsight
point is displayed.

Determine the direction, but
do not store the values. The

graduated circle is orientated.

Using the keyboard, enter the
coordinates for the station or

for the tie point. See chapter "Data
management"
.

Measure the distance
and determine the

direction, and store the measurement
block. The graduated circle is orientated.
The difference between the calculated
distance and the measured distance
to the backsight point is displayed.

Single-point orientation (quick station setup)

This function brings together in a sin-
gle dialog all of the relevant inputs
needed to set up the instrument from
scratch.
Activate the function "Quick-station
setup (QSET)".

Enter the numbers of the station point
and of the backsight point
respectively. The appropriate point is
immediately searched for in the data
file and, if the search is successful,
the coordinates will be assigned to
the station point and backsight point
without this fact being displayed.

\Quick station setup

Station Id :

1

Backs. Id :

A

Inst. Ht. :

1.500

m

Refl. Ht. :

1.000

m

∆∆∆∆∆

HorizDist :

-----

m

Measure to Backs.point

DIST

CONT INPUT

MC

ALL

REC I<>II VIEW

QUIT

MAIN\Quick station setup

Station Id :

1

Inst. Ht. :

1.600

Stn.East

:

726530.424

m

Stn.North :

256431.871

m

Stn.Elev. :

459.173

m

Set Station with REC or CONT

REC

CONT

MC

QUIT

Station data are set.

Station data are set and are
stored in the measurement

file.

Measurement functions

Determine the direction
and store it, including

the previously-measured distance
where appropriate. The graduated
circle is orientated.

Activate controlled data
search within data file.

See chapter "Data management".