83

TPS1100 - User Manual 2.2.1en

System functions

6

10

12

21

26

GSI communication parameters

The standard parameters are
shown above.

For more detailed information about
command- and data structure, please
refer to "WILD Instruments On-Line"
(document no. G-366-0en), a copy of
which is available (in English only)
from your local Leica Geosystems
agency.

The setting for the interface
parameters is valid for
communication with the GSI
command structure. The baud rate
can be chosen from the standard
values between 2400 and 19200.

The settings of the interface
parameters are valid for
communication using the "GeoCOM
command structure". The baud rate
can be chosen from a list of standard
values between 2400 and 19200. All
other parameters are fixed and
cannot be changed.

For more detailed information about
command- and data-structure, please
refer to the handbook "GeoCOM
Reference Manual" (document no. G-
560-0en), a copy of which is available
(in English only) from your local Leica
Geosystems agency.

Interface parameters (GeoCOM)

Communication

\ GSI parameters

Baudrate

:

2400

Protocol

:

GSI

Parity

:

Gerade

Terminator :

CR LF

Data Bits :

7

Stop Bit

:

1

CONT

DEFLT

MC

QUIT