The optional "Extended Range (XR)"-

laser is a visible red laser with

in-creased measurement range. The

coaxial XR - laser makes it possible

to measure distances over 170 m

(560 ft) reflectorless and over 10 km

(6.2 miles) to one prism (refer to the

chapter "Technical specifications").

The operation of an XR - instrument

is equivalent to a conventional TPS

with red laser. Please consider the

following points when measuring with

the XR - laser (RL & Long Range).

The objective lens should

always be clean. Dirt on the

lens (dust, fingerprints, ...) can lead

to reduced accuracy.

Reflectorless

Be sure that the laser beam

is not reflected by anything

close to the line of sight (e.g. highly

reflective objects).

Extended Range (Option)

Long Range to prisms

WARNING:
Due to laser safety

regulations and measuring

accuracy, using the Long Range Pro-

gram is only allowed to prisms that

are more than 1000 m (3300 ft) away.

Whenever possible accurate

measurements to prisms

should be made with the standard

program (IR).

Long Range to reflector tape

The Long Range Program can also

measure to reflector tape. To guaran-

tee the accuracy the laser beam

must be perpendicular to the reflector

tape and the XR - laser must be well

adjusted (refer to the chapter

"Checking and adjusting").

When a distance

measurement is triggered,

the EDM measures to the object

which is in the beam path at that

moment. In case of temporary

obstruction (e.g. a passing vehicle) or

heavy rain, fog or snow, the EDM

may measure to the obstruction.

When measuring longer dis-

tances, any divergence of

the red laser beam from the line of

sight might lead to less accurate

measurements. This is because the

laser beam might not be reflected

from the point at which the

crosshairs are pointing.

Therefore, it is recommended to ver-

ify that the XR - laser is well colli-

mated with the telescope line of sight

(refer to the chapter "Checking and

adjusting"). This should be done at

regular intervals.

Do not measure with two

instruments to the same

target simultaneously.