The LS Series is a multi-function, versatile laser scan micrometer. This
chapter describes the procedures for setting the LS-3100(W)/3101(W) by
illustrating typical applications.

This chapter covers the procedures needed to make measurements after the
memory is initialized (after "MEMORY INITIALIZED" is displayed).

Initializing Current Settings ........................................................................... 8
How to Use This Chapter .............................................................................. 9

Common Settings ......................................................................................... 9

Setting the Number of Measurements for Averaging ............................... 9
Tolerance Settings ................................................................................. 10

Measurement Procedures .......................................................................... 10

Outer Diameter Measurements .............................................................. 10
Gap Measurement 1 .............................................................................. 11
Gap Measurement 2 .............................................................................. 11
Measuring Roundness ........................................................................... 12
Measuring Eccentricity ........................................................................... 12
Measuring Target Displacement within the Measuring Range .............. 13
Measuring Edge Movement ................................................................... 13

Using LS-3100D(W) Controller with 2 Scanning Heads ............................. 14

Once a setup is completed, do not initialize the setting again unless
you need to change them. (When initialized, all the current settings
are cleared.)

Initializing Current
Settings

Turn the power switch "ON" while pressing ENT.

"MEMORY INITIALIZED" is displayed on the sub-display.

All prior settings are cleared and memory initialization is completed.