KEYENCE LS-3100/3100W Series User Manual

Page 31

Advertising
background image

25

Procedure

Switching between 3-step and 7-step differentiations
1. Use PRM to display "LIMIT" (on the subdisplay).

2. To switch between two types of differentiation, use UP/DOWN to move the

cursor up.

3. Each time you press SET, "7 CLASSES" and "3 CLASSES" are displayed

alternately. Choose the desired type of differentiation.

Turning comparator output function ON/OFF
1. Use PRM to display "LIMIT" (on the subdisplay).

2. Use UP/DOWN to move the cursor down.

3. Each time you press SET, "ON" and "OFF" are displayed alternately.

4. Display "ON" to obtain the comparator output function, or "OFF" to cancel

this output function.

Setting tolerance limits (3-step differentiation)
1. First select 3-step differentiation as mentioned above, then use LIMIT to

set the tolerance limits.

➪ See P.29

2. If you press PRM after having set the tolerance limits, "DIGIT SUPPRESS"

will be displayed.

Setting tolerance limits (7-step differentiation)
1. First select 7-step differentiation as mentioned above, then use PRM to

set the tolerance limit.

2. "HI1" and "LO1" will appear on the subdisplay. Use UP/DOWN to move

the cursor up for HI1 or down for LO1.

3. Enter the desired values and press ENT to register.

4. Press PRM.

5. "HI2" and "LO2" will appear on the subdisplay. Enter the desired values

and press ENT to register.

6. Press PRM to display "HI3" and "LO3", enter the desired values, and

press ENT to register.

CHAPTER 4 Functions and Controls

I M I

L

T

O N

7 C L A S S E S

I M I

L

T

O N

7 C L A S S E S

H

2

3 0

=

0 0 0

L O

.

I

3 0

0 0 0

.

=

2

-

0
0

I M I

L

T

O N

7 C L A S S E S