CHAPTER 4 Functions and Controls

Function

Command

Description

Setting arithmetic

C0

Sets method "X"

operation method

C1

Sets method "Y"

C2

Sets method "X+Y"

C3

Sets method "X-Y"

C4

Sets method "(X+Y)/2"

C5

Sets method "(X-Y)/2"

C6

Sets method "-X"

C7

Sets method "-Y"

C8

Sets method "-(X+Y)"

C9

Sets method "-(X+Y)/2"

Setting

MN

Sets NORMAL mode

measurement mode

MP

Sets P-P mode

ME

Sets PEAK mode

MB

Sets BOTTOM mode

Setting tolerance

Hn

Sets value ("n") for HIGH

range for 3-level

(upper tolerance limit)

differentiation

Ln

Sets value ("n") for LOW
(lower tolerance limit)

Setting OFFSET

On

Sets value ("n") for OFFSET value

value

Setting display

Gn

Sets the number of display digits

digit deletion

to be deleted

Note:
• Entry of the bracketed commands ([ ]) can be omitted.

When no command for specifying program No. is entered, the pro-

gram currently used on the front panel is specified.

When no command for specifying output channel is entered, CH1 is

specified.

• When there is an error in the format, all the commands in that format are

disregarded.

• Only one command for setting functions can be entered for one format.

Entry examples
• To specify "3" for program No., CH2 for output channel, and 10.0000 mm

for OFFSET value: "P3WO10.0000 CR"

• To specify 1.2345 mm for LOW1 of tolerance range for 7-level differentia-

tion, while not changing the other settings on the front panel: "TD1.2345
CR"

Commands for setting functions