Measuring edge movement – KEYENCE LS-3100/3100W Series User Manual

Page 19

Advertising
background image

13

CHAPTER 3 Quick Setup Procedures

When the measurement mode is set to "P-P", the displayed value is
retained until HOLD is pressed or until an external signal is input through
the hold synchronous input terminal.

3. Resetting displayed values (When 1. 2 3 4 5 appears on the main

display)

HOLD

HOLD

HOLD

Main display

The displayed
value is reset
to "0".

Measuring Target
Displacement within
the Measuring Range

Applications
• Measuring disk head movement
• Measuring camera lens movement

Setting
1. Initialize settings ("MEMORY INITIALIZED" is displayed.)

Follow the same procedure as that for "Gap Measurement 1".
To reset the current value to "0", press ZERO.

To reset the displayed value to "0" again, press ZERO twice.

+

T

R

ZERO

Measuring Edge
Movement

Applications
• Measuring paper feed for copying machines
• Controlling sheet edges
• Measuring dot printer wire movement

Setting
1. Initialize settings ("MEMORY INITIALIZED" is displayed.)

Follow the same procedure as that for "Gap Measurement 1".
To reset the current value to "0", press ZERO.

To reset the displayed value to "0" again, press ZERO twice.

+

T

R

ZERO

08.10.1, 11:14 AM

13

Advertising