Tolerance settings, 2 measurement procedures, Outer diameter measurements – KEYENCE LS-3100/3100W Series User Manual

Page 16: 2. measurement procedures

Advertising
background image

10

CHAPTER 3 Quick Setup Procedures

Tolerance Settings

The following procedure shows how to set the upper limit to 10.5 mm, and
lower limits to 9.5 mm.

For details on tolerance setting for 7-step differentiation, refer to pages 23
through 26.

3-2. Measurement Procedures

LIMIT

1

0

ENT

9

.

5

5

ENT

H

L

I

O

=
=

6
6

0
0

.
.

0
0

0
0

0
0

0
0

H

L

I

O

=
=

[

– 6 0

.

0 0 0

1
0

H

L

I

O

=
=

[

– 6 0

.

0 0

1
0

0
0

H

L

I

O

=
=

H

L

I

O

=
=

H

L

I

O

=
=

H

L

I

O

=
=

[

1 0

.

5 0 0 0

9

]

]

[

– 6 0

.

0

1
0

0
0

.

0

]

[

– 6 0

.

1
0

0
0

.

0

5
0

]

1
6

0
0

.
.

5
0

0
0

0
0

0
0

]

H

L

I

O

=
=

[

1 0

.

5 0 0

9

0

. ]

H

L

I

O

=
=

[

1 0

.

5 0

9

0

.

0
5 ]

H

L

I

O

=
=

1 0

9

.
.

5
5

0
0

0
0

0
0

H

L

I

O

=
=

[

1 0

.

5 0 0 0

]

.

" " moves
to the "LO"
position

OK

Outer Diameter
Measurements

Applications
• Measuring piston outer diameter
• Measuring flat cable width
• Measuring capacitor outer diameter

Setting
After "MEMORY INITIALIZED" is displayed, the segment mode is automati-
cally set to DIA (outer diameter measurement).

For details on AVERAGE setting, refer to "AVERAGE", and for details on
tolerance setting, refer to "Tolerance Settings" shown above.

• The number of measurements for averaging is set to 1024 after settings

are initialized.
"----" appears on the display for about 3 seconds, even after a target is
placed within the measuring range.

• In the DIA mode, "----" appears on the main display when no workpiece is

within the measuring range.