Act setting, Act setting -12 – KEYENCE AutoID User Manual

Page 62

Advertising
background image

4-12

SETT

ING DEVICE OPER

A

T

IONS

4

4-3

BL Series Settings

Act Setting

This section describes the [Act setting] tab for the barcode reader.

Item

Description

Read mode

Select the read mode.
When "Single" is selected, set "Data-send timing".
When "Multi1" or "Multi2" is set, set "Repeat-reading interval".

Additional information

Set the additional information.
"Scan count" can be set only when "Decoding count" is set.
"Symbology ID" and "PMI" can be set only on the BL-600.
When the "PMI" checkbox is marked, set each preventive maintenance
information (PMI) value within the range 0 to 100.

Decoding match count

Enter any desired numerical value within the range 1 to 255 (times).
Normally, use the default (2 times).

Though a larger "Decoding match count" setting increases the reliability of
reading, the reading speed slows down. Alternatively, a smaller setting increases
the reading speed but lowers the reliability of reading.

On the BL Series, when the scan count (decoding counting) in which the barcode
was successfully decoded (read) becomes the value set at "Decoding match
count", the barcode is judged to have been read.

Read error

This item is for setting the error code that is sent to the personal computer by the
barcode reader when a barcode cannot be read.
Any error code up to eight characters in length can be set. However, normally,
use the default (ERROR). Leaving the text box blank disables sending of an error
code.

Data-send timing

This item must be set only when Read mode is set to "Single".

Repeat-reading interval

Set 1 to 255 (100 to 25500 ms) for Repeat-reading interval.
This item must be set only when Read mode is set to "Multi1" or "Multi2".

"Trigger setup" button

The trigger input can be set up by clicking this button.

Advertising