Other settings, Other settings -17, Special setting – KEYENCE AutoID User Manual

Page 67

Advertising
background image

4-17

4-3

BL Series Settings

SETT

ING DEVICE OPER

A

T

IONS

4

Other Settings

This section describes the [Other settings] tab for the barcode reader.

Special setting

The items that are displayed under Special setting differ according to the BL Series model.

Item

Description

OK/NG output duration

Set 1 to 255 (10 to 2550 ms) for OK/NG output duration.

STABILITY LED

When "Use stability LED" is selected, the reading stability is indicated by the
STABILITY LED when the BL Series is reading barcodes normally.

Preset data

Set the barcode data to register within 32 characters.
* Preset data can be set up to 64 characters when the barcode type is

CODE128 and the start code is CODE-C.

"Special setting" button

When this button is clicked, the special settings are displayed.

Item

Description

Read reverse barcode

When "Enable" is selected, reversed barcodes (black swapped with white, and
vice versa) can be read.

Quiet zone scale

Set the minimum value for expansion of the quiet zone that can be read by the
BL Series. Enter the number of times the quiet zone can expand by with respect
to the narrow bar width (smallest bar width of a bar code) of the barcode.
* Change this item only when the quiet zone of the barcode in use is narrow.

Normally, do not change this item.

Decode cancel count

Do not change this item.

Test SW output

When "Enable" is selected, data such as the barcode read by the BL Series and
the read rate is sent to the personal computer.
To disable transmission of data, do not select "Enable".
* This item is applied to all reading operations that use the TEST switch.

Advertising