Host setup, Plc setup – KEYENCE AutoID User Manual

Page 66

Advertising
background image

4-16

SETT

ING DEVICE OPER

A

T

IONS

4

4-3

BL Series Settings

Host setup

The following describes setting of "Host setup" when PLC Link is set to "Disable".

PLC setup

The following describes setting of "PLC setup" when PLC Link is set to "Use".

Item

Description

Handshaking

Select the communication format (protocol) when sending read barcode data to
the personal computer.

Checksum

Data for checking for corrupted data in serial communications can be
appended.

Header

Select the send format of read barcode data.
When "Custom" is selected, set the header using up to five characters in each
of the text boxes (ASCII or HEX).

Delimiter

"Option" button

When this button is clicked, the [Send delay time] can be set.
Set the time to wait for sending the response that is returned by the BL Series
to commands sent to the BL Series from the personal computer within the
range 0 to 255 ms.

Item

Description

PLC type

Select the type of PLC to be connected.

PLC trigger area

Select this item to apply a trigger for reading barcodes on the BL Series in a
PLC Link.

DM head address

Set the DM head address within the range 0000 to 9900.

Station No.

Set the station No. within the range 0 to 31.
* This item is not displayed when "KEYENCE KV Series" is selected at PLC

type.

File register

To use a file register as a device, select "Enable". When a file register is used

,

set the block No. of the file register within the range 0 to 255.