4-16
SETT
4
4-3
BL Series Settings
■ Host setup
The following describes setting of "Host setup" when PLC Link is set to "Disable".
■ PLC setup
The following describes setting of "PLC setup" when PLC Link is set to "Use".
Item
Description
Handshaking
Select the communication format (protocol) when sending read barcode data to
the personal computer.
Checksum
Data for checking for corrupted data in serial communications can be
appended.
Header
Select the send format of read barcode data.
When "Custom" is selected, set the header using up to five characters in each
of the text boxes (ASCII or HEX).
Delimiter
"Option" button
When this button is clicked, the [Send delay time] can be set.
Set the time to wait for sending the response that is returned by the BL Series
to commands sent to the BL Series from the personal computer within the
range 0 to 255 ms.
Item
Description
PLC type
Select the type of PLC to be connected.
PLC trigger area
Select this item to apply a trigger for reading barcodes on the BL Series in a
PLC Link.
DM head address
Set the DM head address within the range 0000 to 9900.
Station No.
Set the station No. within the range 0 to 31.
* This item is not displayed when "KEYENCE KV Series" is selected at PLC
type.
File register
To use a file register as a device, select "Enable". When a file register is used
,