4-29
4-5
RS-485 Controller (NX-50RS) Settings
SETT
4
RS-485 Setting
The following describes the settings of the [RS-485 setting] tab for the NX-50RS.
"NX-50 Series Operation Manual"
The RS-485 settings of NX-50RS can be unified by the "Apply to all the slaves" button
on the [RS-485 setting] tab for the N-410.
"4-8 RS-485 Master Unit (N-410) Settings" "RS-485 Setting" (page 4-46)
Item
Description
Slave ID
Select 0 to 31 as the slave ID of the NX-50RS. When "0" is set, the NX-50RS is
set in a standalone configuration (i.e. not a multi-drop configuration).
Baud rate
Select the baud rate (bit/s) from the pulldown menu.
Parity
Select None, Even or Odd for Parity.
Data bits
Select 7 bits or 8 bits for Data bits.
Stop bit
Select 1 bit or 2 bits for Stop bit.
Tip