Terminal Setting

The following describes the settings of the [Terminal setting] tab for the NX-50DN.

Item

Description

Input select

Select For head or For general-use for the IN1 and IN2 terminal functions.

Input state

Select Norm. open or Norm. close for the input state of the IN1 and IN2
terminals.

Input pulse width

Select 2ms or 10ms for the input time constant of the IN1 and IN2 terminals.

Output select

Select From head, Host or Bus master for the functions of the OUT1 to OUT4
terminals.

Output state

Select Norm. open or Norm. close for the output state of the OUT1 to OUT4
terminals.