SETT

ING DEVICE OPER

A

T

IONS

4

4-4

SR-500 Series Settings

Timing Setting

This section describes the settings for the read timing conditions.

Item

Description

Signal type

Select Level or One-shot. When selecting One-shot, set One-shot input time
as well.

Input state

Select Normally open or Normally closed.

Input pulse width

Select 2 ms or 10 ms.

Trg delay time

Set the trigger delay time (0 to 9990 ms, 10 ms increment)

Test mode initiated

Set this when initiating the test mode when a trigger is input or the power
turns ON.

Cmd for trigger ON

Change the trigger input ON command within eight characters.
The default is LON.

Cmd for trigger OFF

Change the trigger input OFF command within eight characters.
The default is LOFF.

Power-on trigger

Turns on the trigger when the power turns on.